PRODUCT

Features & Benefit

Compact and Light
Light weight and it is convenient to carry it anywhere.




Powerful Protection
Ensuring operators safety from the leakage radiation.
Easy to Use

Power on

Select Case 1 ~ Case 4

Press X-ray Exposure button
To make an X-ray, just 3 steps are enough.
1. Power on
2. Select Case 1 ~ 4
3. Press X-ray exposure button



Specification
Contents | Specification | |
Exposure time (sec) | 0.01~1.30 sec (43 steps) | |
X-ray Tube | Model | Canon D – 041 |
kV & mA | 70kV & 2mA | |
Focal Spot | 0.4mm | |
Total Filtration | 1.5mm AL Eq. | |
Weight | 1.97kg |
Contents | Specification | |
Exposure time (sec) | 0.01~1.30 sec (43 steps) | |
X-ray Tube | Model | Canon D – 041 |
kV & mA | 70kV & 2mA | |
Focal Spot | 0.4mm | |
Total Filtration | 1.5mm AL Eq. | |
Weight | 1.97kg |
Package Contents


Safety

We always think first your
safe dental practice
400,000
EXPOSURES A YEAR
=20 mSv
SO IT IS SAFE
POINT | S1.0 sec / 5,200 exposures a yearn | |
TOP (A) | 0.3 mSv | |
LEFT (B) | 0.4 mSv | |
RIGHT (C) | 0.3 mSv | |
BOTTOM (D) | 0.2 mSv | |
BACK (E) | 0.1 mSv | |
AVERAGE | 0.26 mSv |
POINT | S1.0 sec / 5,200 exposures a yearn | |
TOP (A) | 0.3 mSv | |
LEFT (B) | 0.4 mSv | |
RIGHT (C) | 0.3 mSv | |
BOTTOM (D) | 0.2 mSv | |
BACK (E) | 0.1 mSv | |
AVERAGE | 0.26 mSv |
** Test condition
– 1.0 second
– Distance : (A), (B), (C), (D) – 50cm/(E)
– 108cm behind of REXTAR-X
** Note : Occupational dose limit per year (UK or European standard) = 20 mSv
Your Safety Our Priority


** REXTAR X Test condition
– 1.0 second
– Distance : 50cm behind of REXTAR X 8 points / 108cm behind of REXTAR X bark part
– Lead / acrylic backscatter shield was fixed at the end of cone
Quality
Focal Spot


- Focal spot size is very important in any X-ray.
- Smaller focal spot with the smaller angle degree can provide the sharpest images whatever could be.
- Because smaller divergence angle of the X-ray beams make edges of the image on the detector more accurately.
- You can get higher contrast and density of dental X-ray image by using the focal spot 0.4 mm comparing with 0.8mm portable X-ray devices.
Current & Voltage

Lower Current and Voltage

Higher Current and Voltage
- Current
- Current is a flow of electric charge which means the quantity.
- In order to get a clear image, current of tube is also important factor.
- Moderate quantity of X-ray beams helps to capture the image more clearly.
- Voltage
- Tube voltage is the power of penetrating the bone.
- Powerful voltage helps you obtain high-resolution X-ray image.
- The main advantage of powerful voltage is to eliminate blurred and unclear pictures.
The best Tube quality of REXTAR X easily penetrates the bone and provides the superior x-ray images.
Handy
Anytime, Anywhere · Light Weight · Easy to Use

Dental Clinic
Free from the X-ray room

Ambulance
Don’t let the Golden Time pass by

Field Hospital
Save your patriots lives

Veterinary Hospital
Take care of your lovers

Forensic Science
Find the Truth

Industrial Inspection
Inspect invisible defect

Dental Clinic
Free from the X-ray room

Ambulance
Don’t let the Golden Time pass by

Field Hospital
Save your patriots lives

Veterinary Hospital
Take care of your lovers

Forensic Science
Find the Truth

Industrial Inspection
Inspect invisible defect